Anti Static Epoxy Floor Top Coating

Product ID: 4761

The Anti-Static Epoxy Floor Top Coating (designated as AAETC™ code) is a two-component epoxy resin system that combines epoxy resin with a special hardener. This top coating is specifically formulated with conductive additives, special pigments, and other additives. By incorporating these conductive materials, the epoxy flooring can dissipate static electricity within the 10,000 to 1,000,000 ohms range. Static electricity can be generated through various sources such as wear, traffic, transportation, and friction.
The primary application of this anti-static epoxy coating is on copper sheets, kits, and electric circuits. It is commonly referred to as an anti-spark coating due to its effective static electricity dissipation properties.

Product introduction Anti Static Epoxy Floor Top Coating

[scroll_to link=”#overview” bullet=”false”]

[row padding=”0 0px 0px 0px”]

[col span__sm=”12″]

PRODUCT DESCRIPTION

[/col]
[col span__sm=”12″ margin=”0px 0px 50px 0px”]

Our Anti-static Epoxy Floor Covering is a high-performance solution designed to meet the demanding requirements of various industries. This specialized flooring system offers exceptional conductivity while providing superior protection against corrosion, damage, and wear.
Formulated with advanced anti-static properties, this epoxy floor covering effectively dissipates static electricity, ensuring a safe and controlled working environment. It prevents the buildup of static charges that can potentially damage sensitive electronic equipment or pose a risk to personnel.
Additionally, our Anti-static Epoxy Floor Covering offers excellent acid resistance, making it suitable for environments where chemical spills or exposure to corrosive substances may occur. The durable coating acts as a protective barrier, safeguarding the underlying structure and extending the floor’s lifespan.
Its seamless and smooth surface makes this floor covering easy to clean and maintain, promoting a hygienic and visually appealing environment. Its anti-slip properties enhance safety, reducing the risk of slips and falls, even in areas of frequent traffic.
Ideal for a wide range of applications, including laboratories, cleanrooms, manufacturing facilities, data centers, healthcare facilities, and electronic assembly areas, our Anti-static Epoxy Floor Covering combines functionality, durability, and aesthetics to meet the unique needs of your industry.
Trust in our high-quality anti-static epoxy floor covering to create a reliable, static-free, and long-lasting flooring solution that surpasses industry standards.

Compatibility with Other Protective Coatings

Our Anti-static Epoxy Floor Covering offers excellent compatibility with a range of protective coatings, allowing for easy re-covering or application of additional layers. When considering re-covering options for an existing anti-static epoxy floor, the following products are recommended:
1. Alkyd, Phenolic Alkyd, Silicone Alkyd, and Urethane Alkyd: These coatings are compatible and can be used for recovering the anti-static epoxy floor, providing a durable and protective layer.
2. Two-Component Epoxy: This type of coating is suitable for re-covering the anti-static epoxy floor, ensuring a seamless and long-lasting finish.
3. Polyurethane: Polyurethane coatings are compatible and can be applied as an additional layer over the anti-static epoxy floor, enhancing its durability and chemical resistance.
4. Acrylic: Acrylic coatings can be used for re-covering the anti-static epoxy floor, offering excellent adhesion and protection.
For the immediate application of another layer after applying the anti-static floor coating, the following protective coatings are recommended:
1. Two-Component Acrylic: This coating provides a protective layer with excellent adhesion and resistance properties, complementing the anti-static properties of the floor coating.
2. Acrylic Latex: Acrylic latex coatings are suitable for immediate application over the anti-static epoxy floor, offering a protective barrier and enhancing the aesthetics of the flooring.
3. Chloro Ruber (Chlorocaoutchouc): Chloro Ruber coatings can be used as an additional layer, providing enhanced chemical resistance and protection for the anti-static floor.
4. Polyamide Epoxy High Build: This coating is compatible with the anti-static epoxy floor, offering a high-build protective layer with superior resistance to abrasion and chemicals.
5. Two-Component Polyurethane: Two-component polyurethane coatings can be applied immediately after the anti-static floor coating, providing exceptional durability and chemical resistance.

[/col]
[col span=”6″ span__sm=”12″ margin=”0px 0px -14px 0px” max_width=”450px” class=”product-future”]

Features


  •  Transfer of static electricity
  •  Prevent static electricity sparks

[/col]
[col span=”6″ span__sm=”12″ margin=”0px 0px -14px 0px” max_width=”450px” class=”product-future”]

Applications


  • Antistatic epoxy flooring for concrete floors of various factories
  • Antistatic epoxy flooring protective coating of production halls of military units
  •  Antistatic epoxy flooring for electronic kits and circuits
  •  Antistatic epoxy flooring for warehouses of flammable materials
  •  Antistatic epoxy flooring and protective coating of control rooms
  •  Antistatic epoxy flooring for color mixing rooms

[/col]

[/row]
[row padding=”0 0px 0px 0px”]

[col span=”6″ span__sm=”12″ margin=”0px 0px -14px 0px” max_width=”450px” class=”product-future”]

Packaging


[/col]
[col span=”6″ span__sm=”12″ margin=”0px 0px -14px 0px” max_width=”450px” class=”product-future”]

Colour


  • Black

[/col]

[/row]
[gap height=”50px”]

[scroll_to link=”#productdetails” bullet=”false”]

[title style=”center” text=”technical specifications” margin_top=”90px”]

[accordion]

[accordion-item title=”Physical Properties”]

color black

Mixing ratio

A:B= 100:18
density

1.2g/cm3

Electrical resistance range

1MΩ
 Initial setting time

6 hours

Final setting time

24 hours
Shelf time

1 year

[/accordion-item]
[accordion-item title=”Mechanical Properties”]

[/accordion-item]
[accordion-item title=”For Engineers”]

  •  Understand Requirements: Familiarize yourself with project requirements and environmental factors.
  •  Surface Preparation: Ensure clean and dry substrate before applying the coating.
  • manufacturer’s instructions for precisely mixing components.
  •  Application Techniques: Apply coating evenly using suitable tools.
  • Allow Sufficient Curing Time: Provide recommended curing time for optimal performance.
  •  Regular Maintenance: Implement routine cleaning and inspections.
  •  Safety Precautions: Use appropriate PPE and ensure proper ventilation.
  •  Compliance with Standards: Ensure the coating meets required industry standards.
  • Ongoing Education and Training: Stay updated with advancements in the field.
  • Collaborate with Experts: Seek guidance from experienced professionals.

[/accordion-item]
[accordion-item title=”For Contractors”]

  • Understand project requirements.
  • Ensure proper surface preparation.
  • Accurately mix components.
  • Apply coating with skillful techniques.
  • Allow sufficient time for curing.
  • Implement quality control and inspections.
  • Provide clear maintenance guidelines.
  • Comply with safety regulations.
  • Seek expert guidance when needed.
  • Continuously update knowledge and skills.

[/accordion-item]
[accordion-item title=”Application Instructions”]

First, thoroughly combine the two components of the product and mix them in a mixer for 5 minutes. It is recommended to allow the mixture about 20 minutes for the reaction between the two components. Apply the protective coating using a roller, brush, or spray gun. It should be noted that the epoxy primer prepared for the concrete surface should be used within less than 4 hours after preparation. Preparing the substrate surface before an application is preferable by using a scraper or sub-segmentation device. This action aims to create a surface for strong mechanical bonding.

[/accordion-item]
[accordion-item title=”Guide to Quality Control (QC)”]

  • Pre-Installation Inspection: Inspect the substrate before installation.
  • Material Verification: Verify the coating materials.
  • Adherence to Mixing Ratios: Follow precise mixing instructions.
  • Batch Consistency: Use the same batch for consistency.
  • Wet Film Thickness (WFT) Measurement: Measure coating thickness.
  • Cure Time Monitoring: Monitor curing time.
  • Adhesion Testing: Assess bonding strength.
  • Surface Resistivity Testing: Measure resistivity.
  • Visual Inspection: Inspect for defects and uniformity.
  • Documentation: Maintain records of inspections and tests.
  • Compliance with Standards: Ensure adherence to industry standards.
  • Ongoing Monitoring and Maintenance: Continuously monitor and maintain the coating.

[/accordion-item]

[/accordion]
[gap height=”50px”]

[scroll_to link=”#documents” bullet=”false”]

[title style=”center” text=”technical documents” margin_top=”90px”]

[row style=”large” col_bg=”rgb(249, 249, 249)”]

[col span=”4″ span__sm=”12″ divider=”0″ padding=”20px 20px 20px 20px” align=”center” bg_color=”rgb(249, 249, 249)” class=”pad” depth=”1″]

Technical Data Sheet (TDS)

[button text=”Download” class=”but-en” style=”outline” radius=”99″ link=”https://afzir.com/wp-content/uploads/2017/01/Afzir-ASPECTM.pdf”]

[/col]
[col span=”4″ span__sm=”12″ padding=”20px 20px 20px 20px” align=”center” bg_color=”rgb(249, 249, 249)” color=”light” class=”pad” depth=”1″]

Safety Data Sheet (SDS)

[button text=”Download” style=”outline” radius=”99″ link=”#download”]

[/col]
[col span=”4″ span__sm=”12″ padding=”20px 20px 20px 20px” align=”center” bg_color=”rgb(249, 249, 249)” class=”pad” depth=”1″]

Drawings

[button text=”Download” style=”outline” radius=”99″ link=”#download”]

[/col]

[/row]
[gap height=”50px”]

[scroll_to link=”#gallery” bullet=”false”]

[title style=”center” text=”Photo Gallery” margin_top=”90px”]

[ux_gallery ids=”3581,3580,3579,3583,3584″ style=”default” type=”slider” columns=”5″ image_height=”100%” image_radius=”2″ image_hover=”zoom” text_color=”dark”]

[lightbox id=”download” width=”750px” padding=”0″]
[section bg_color=”#f47425″ padding=”5″]

Technical documentation request

[/section]

[row bg_color=”#f47425″ padding=”5″ class=”tick-list”]

[col span=”1/1″ ]

    [/col]

    [/row]

    [/lightbox]

    Frequently Asked Questions

    [sc_fs_multi_faq headline-0=”h2″ question-0=”Antistatic epoxy floor covering is made of what components?” answer-0=”Antistatic epoxy floor coating (AAETC ™ code) is made in two components and from the combination of two components of epoxy resin and hardener or special hardener. Antistatic epoxy floor covering is designed and manufactured using conductive additives and special pigments and additives. ” image-0=”” headline-1=”h2″ question-1=”What is another name for antistatic coating?” answer-1=”This type of primer is also known as anti-spark primer due to its ability to transfer static electricity.” image-1=”” headline-2=”h2″ question-2=” What is the mixing ratio of the components?” answer-2=”The components are combined in the ratio A:B=100:18. In fact, for every 100 parts of epoxy resin, 18 parts of hardener or hardener are needed.” image-2=”” headline-3=”h2″ question-3=”What products do you recommend to replace the antistatic epoxy floor covering with a new floor?” answer-3=”If epoxy flooring is used as a coating in a project and after some time it is decided to cover it again, you can use alkyd, phenolic alkyd, silicone alkyd and urethane alkyd, two-component epoxy, polyurethane and acrylic products for coating used again.” image-3=”” headline-4=”h2″ question-4=”What are the special uses of antistatic floor covering?” answer-4=” This coating is used as operating room flooring.” image-4=”” headline-5=”h2″ question-5=”How long does the antistatic floor coating take?” answer-5=”The anti-static floor coating product reaches the initial setting after 6 hours and the final setting after 24 hours.” image-5=”” headline-6=”h2″ question-6=”In what colors is the antistatic epoxy flooring available?” answer-6=”This product is available in black and other colors. ” image-6=”” headline-7=”h2″ question-7=”In what temperature conditions is it not allowed to use antistatic flooring?” answer-7=”If the weather is very humid (relative humidity above 85%), this coating should not be used.” image-7=”” count=”8″ html=”true” css_class=””]
    Product Review

    Reviews

    There are no reviews yet.

    Be the first to review “Anti Static Epoxy Floor Top Coating”

    Your email address will not be published. Required fields are marked *

    Share On: